Doors, Surrounds, and Front |
1. Verify no obstructions to airflow through the louvers. |
2. Verify maintenance of proper clearance to combustible household objects. |
Gasket Seal, Glass Assembly and Glass |
1. Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat. |
2. Inspect gasket seal and its condition. |
3. Verify that latches engage properly, clip studs are not stripped, and glass attachment components are intact and operating properly. |
4. Clean glass. Recommend glass replacement glass if severely coated with carbon deposits that cannot be removed. |
Valve Compartment and Firebox Top |
1. Vacuum and wipe out dust, cobwebs, debris or pet hair. |
2. Remove any foreign objects. |
3. Verify unobstructed air circulation. |
Logs |
1. Inspect for broken, damaged, or missing logs. |
2. Verify correct log placement and no flame impingement causing sooting. Correct as necessary. |
Burner Ignition and Operation | 1. Verify burner is properly secured and aligned with pilot or igniter. |
2. Clean off burner top, inspect for plugged ports, corrosion or deterioration. Recommend replacement burner if necessary. |
3. Replace ember materials with new pieces. Ensure no obstruction to ports or obstruction of lighting paths. |
4. Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay. |
5. Inspect for lifting/ghosting or other flame problems. |
6. Adjust air shutter for best flame performance. |
7. Inspect orifice for soot, dirt or corrosion. |
8. Inspect pilot for optimal performance. |
9. Inspect thermocouple/thermopile for soot, corrosion and deterioration. Clean with emery cloth. Recommend replacement as necessary. |
10. Verify millivolt output. Recommend replacement as necessary. |
Venting |
1. Confirm that termination cap remains clear and unobstructed by plants, etc. |
2. Verify that termination cap clearance to subsequent construction (building additions, decks, fences or sheds) has been maintained. |
Remote controls |
1. Verify operation of remote. |
2. Replace batteries in remote transmitters and battery-powered receivers. |
3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. |